Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Process steam from Heavy fuel oil 90 %; heat plant; consumption mix, at power plant; MJ, 90 % efficiency (Location: ES) A detailed heat plant model was used, which combines measured emissions taken from national statistics plus calculated values for not measured emissions of e.g. simple organics or heavy metals. In general, the efficiencies are 85%, 90% and 95%. Technical Purp... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Electricity Mix; AC; consumption mix, at consumer; 230V (Location: NL) Good overall data quality. Energy carrier mix information based on official statistical information including import/export. Detailed power plant models were used, which combine measured emissions plus calculated values for not measured emissions of e.g. organ... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Process steam from light fuel oil; heat plant; consumption mix, at plant; MJ (Location: BG) Good overall data quality. Energy carrier mix information based on official statistical information including import / export. A detailed heat plant model was used, which combine measured emissions plus calculated values for not measured emissions of e.g. orga... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Electricity Mix; AC; consumption mix, at consumer; 1kV - 60kV (Location: BE) Good overall data quality. Energy carrier mix information based on official statistical information including import/export. Detailed power plant models were used, which combine measured emissions plus calculated values for not measured emissions of e.g. organ... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Process steam from light fuel oil; heat plant; consumption mix, at plant; MJ (Location: AT) Good overall data quality. Energy carrier mix information based on official statistical information including import / export. A detailed heat plant model was used, which combine measured emissions plus calculated values for not measured emissions of e.g. orga... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Waste water treatment; industrial waste water according to the Directive 91/271/EEC concerning urban waste water treatment; at waste water treatment p... The data set covers all relevant process steps / technologies over the supply chain of the represented end-of-life inventory with a good overall data quality. The inventory is mainly based on industry data and is completed, where necessary, by secondary data. ... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Process steam from natural gas 90%; heat plant; consumption mix, at power plant; MJ, 90 % efficiency (Location: CZ) A detailed heat plant model was used, which combines measured emissions taken from national statistics plus calculated values for not measured emissions of e.g. simple organics or heavy metals. In general, the efficiencies are 85%, 90% and 95%. Technical Purp... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Electricity grid mix 1kV-60kV; AC; consumption mix, at consumer; 1kV - 60kV (Location: NO) Data sets represents the average country or region specific electricity supply for final consumers, including own consumption, net losses and imports from neighbouring countries. The national energy carrier mixes used for electricity production as well as data... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Process steam from heavy fuel oil; heat plant; consumption mix, at plant; MJ (Location: CZ) Good overall data quality. Energy carrier mix information based on official statistical information including import / export. A detailed heat plant model was used, which combine measured emissions plus calculated values for not measured emissions of e.g. orga... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Electricity Mix; AC; consumption mix, at consumer; 220V (Location: HU) Good overall data quality. Energy carrier mix information based on official statistical information including import/export. Detailed power plant models were used, which combine measured emissions plus calculated values for not measured emissions of e.g. organ... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Electricity Mix; AC; consumption mix, at consumer; 230V (Location: DK) Good overall data quality. Energy carrier mix information based on official statistical information including import/export. Detailed power plant models were used, which combine measured emissions plus calculated values for not measured emissions of e.g. organ... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 3 E PLCA Polypropylene fibres (PP); crude oil based; production mix, at plant; PP granulate without additives (Location: EU-27) The data set covers all relevant process steps / technologies over the supply chain of the represented cradle to gate inventory with a good overall data quality. The inventory is mainly based on industry data and is completed, where necessary, by secondary dat... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Electricity Mix; AC; consumption mix, at consumer; 220V (Location: SK) Good overall data quality. Energy carrier mix information based on official statistical information including import/export. Detailed power plant models were used, which combine measured emissions plus calculated values for not measured emissions of e.g. organ... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Small lorry transport; Euro 0, 1, 2, 3, 4 mix; 7,5 t total weight, 3,3 t max payload (Location: RER) The data set represents the applied technology with a good overall data quality. The inventory is based on industry and literature data. Technical Purpose: Road transport of bulk commodities or packaged goods with a payload of up to 3,3 t. Geographical Repre... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Process steam from light fuel oil; heat plant; consumption mix, at plant; MJ (Location: GB) Good overall data quality. Energy carrier mix information based on official statistical information including import / export. A detailed heat plant model was used, which combine measured emissions plus calculated values for not measured emissions of e.g. orga... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Small lorry transport; Euro 0, 1, 2, 3, 4 mix; 7,5 t total weight, 3,3 t max payload (Location: RER) The data set represents the applied technology with a good overall data quality. The inventory is based on industry and literature data. Technical Purpose: Road transport of bulk commodities or packaged goods with a payload of up to 3,3 t. Geographical Repre... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Lorry transport; Euro 0, 1, 2, 3, 4 mix; 22 t total weight, 17,3 t max payload (Location: RER) The data set represents the applied technology with a good overall data quality. The inventory is based on industry and literature data. Technical Purpose: Road transport of bulk commodities or packaged goods with a payload of up to 17,3 t. Geographical Repr... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Process steam from heavy fuel oil; heat plant; consumption mix, at plant; MJ (Location: CH) Good overall data quality. Energy carrier mix information based on official statistical information including import / export. A detailed heat plant model was used, which combine measured emissions plus calculated values for not measured emissions of e.g. orga... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Process steam from Light fuel oil 90 %; heat plant; consumption mix, at power plant; MJ, 90 % efficiency (Location: SK) A detailed heat plant model was used, which combines measured emissions taken from national statistics plus calculated values for not measured emissions of e.g. simple organics or heavy metals. In general, the efficiencies are 85%, 90% and 95%. Technical Purp... WEB DWN
Last updated: 19 Aug 2019 | Recent visits: 2 E PLCA Process steam from natural gas; heat plant; consumption mix, at plant; MJ (Location: BE) Good overall data quality. Energy carrier mix information based on official statistical information including import / export. A detailed heat plant model was used, which combine measured emissions plus calculated values for not measured emissions of e.g. orga... WEB DWN