Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-EU-SP-Standard-270 Small punch tensile/fracture test data for P92 material at 23 °C and a displacement rate of .00833 mm/s (third repeat test) Small punch tensile and creep data obtained in a round robin exercise for the elaboration of an EN standard on small punch testing. For estimating the tensile properties a series of tests were carried out at room temperature on Gr. 91 steel with different hea... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-EU-SP-Standard-270 Small punch tensile/fracture test data for P92 material at 22.5 °C and a displacement rate of .00833 mm/s (repeat test) Small punch tensile and creep data obtained in a round robin exercise for the elaboration of an EN standard on small punch testing. For estimating the tensile properties a series of tests were carried out at room temperature on Gr. 91 steel with different hea... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-EU-SP-Standard-270 Small punch tensile/fracture test data for P92 nt material at 20.5 °C and a displacement rate of .00833 mm/s Small punch tensile and creep data obtained in a round robin exercise for the elaboration of an EN standard on small punch testing. For estimating the tensile properties a series of tests were carried out at room temperature on Gr. 91 steel with different hea... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-EU-SP-Standard-270 Small punch tensile/fracture test data for P92 material at 22.7 °C and a displacement rate of .00833 mm/s Small punch tensile and creep data obtained in a round robin exercise for the elaboration of an EN standard on small punch testing. For estimating the tensile properties a series of tests were carried out at room temperature on Gr. 91 steel with different hea... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-EU-SP-Standard-270 Small punch creep test data for P92 ar material at 600 °C and a load of 450 N Small punch tensile and creep data obtained in a round robin exercise for the elaboration of an EN standard on small punch testing. Creep tests were carried out at temperatures in the range 550-650 ºC. WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 3 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -170 °C and a displacement rate of .5 mm/s (repeat test) In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-EU-SP-Standard-270 Small punch tensile/fracture test data for P92 material at 23 °C and a displacement rate of .00833 mm/s (second repeat test) Small punch tensile and creep data obtained in a round robin exercise for the elaboration of an EN standard on small punch testing. For estimating the tensile properties a series of tests were carried out at room temperature on Gr. 91 steel with different hea... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -196 °C and a displacement rate of .005 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -20 °C and a displacement rate of .005 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -100 °C and a displacement rate of .5 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -120 °C and a displacement rate of .5 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at 23 °C and a displacement rate of .5 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -132 °C and a displacement rate of .005 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -60 °C and a displacement rate of .005 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at 23 °C and a displacement rate of .005 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -100 °C and a displacement rate of .005 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -60 °C and a displacement rate of .5 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -130 °C and a displacement rate of .5 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffracti... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -196 °C and a displacement rate of .5 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffract... WEB DWN
Last updated: 7 Feb 2019 | Recent visits: 2 O DIN-PTT-SANSIF-190 Small punch tensile/fracture test data for Gr. 91 material at -150 °C and a displacement rate of .5 mm/s In the framework of its institutional project on Gen IV nuclear reactors, the JRC-IET performs pre-normative materials qualification research within the work package PreMaQ. The activities focus on evaluation methods like ultrasonic fatigue, neutron diffract... WEB DWN